PG
Instruments Limited offer a comprehensive range
of UV and Visible Spectrophotometers
|
T60 New
Century

The T60
New Century is an affordable Dual Beam UV
Visible Spectrophotometer with a fixed slit
of 2nm. The instruments offers a wavelength
range of 190 - 1100nm. The T60 has a small
footprint and has pre-programmed PCMA cards
for quantitative analysis, scanning,
kinetics and DNA. The T60 can be interfaced
to a PC via UV Spec Software. The system is
supplied with an 8 cell motorised cell
changer as standard. The T60 boasts a
performance on a par with larger and more
expensive machines. Everything from simple
concentration measurements up to
sophisticated analyses.
Top of Page |
T60 Aurora

The T60
Aurora
is a Dual Beam Visible range Spectrophotometer with a fixed slit
of 2nm. The instruments offers a wavelength
range of 325- 1100nm. The T60 has a small
footprint and has pre-programmed PCMA cards
for quantitative analysis, scanning,
kinetics and DNA. The T60 can be interfaced
to a PC via UV Spec Software. The system is
supplied with an 8 cell motorised cell
changer as standard. The system is simple to
operate yet can be used for simple
concentration analysis up to sophisticated
analyses.
Top of Page |
|
T70 UV
Spectrophotometer

The T70 UV
Spectrophotometer is a dual beam instrument
with a fixed 2nm bandpass. The wavelength range
is 190 - 1100nm.The T70 has a large 'fold
away' LCD display unit which allows fos
complete display of Spectra. The system has
a large easy to use positive touch key pad
and the instrument can be used a complete
standalone unit.
Top of
Page |
T70+ UV
Spectrophotometer

The T70 UV
Spectrophotometer is a dual beam instrument
with a variable band-pass of 0.5, 1.0,
2.0 and 5.0nm. The wavelength range
is 190 - 1100nm.The T70 has a large 'fold
away' LCD display unit which allows fos
complete display of Spectra. The system has
a large easy to use positive touch key pad
and the instrument can be used a complete
standalone unit.
Top of Page |
|
T80
Double Beam UV Spectrophotometer

Top of Page |
T80+ Double Beam UV
Spectrophotometer

Top of Page
|
|
T100
Portable Spectrophotometer

PG Instruments Limited have recently
introduced the T100 Portable
Spectrophotometer. This instruments offers
excellent performance yet is competitively
priced. The compact portable
spectrophotometer is extensively used for
on-line monitoring, environmental
protection, agriculture and many other
applications

Top of Page
|
T100 Portable
Spectrophotometer

The main features of the system are:
-
Portable Compact, light, and large capacity
rechargeable battery, External charger and
Car power supply can fully meet the
requirements of using in labs and in the
field.
-
Multiple functions Spectrum scanning,
photometric measurements, quantitative
measurement, kinetic measurement and peak
picking etc.
-
High-speed measurement The NMOS PDA receiver
and the full range spectrum displayed in 0.1
second make the online measurement possible.
-
Holographic concave panel grating The
holographic concave panel grating ensures
the quality spectrum.
-
The anti-corrosive immersed fiber-optics
probe. The on-line measurement needn’t
colorimetric tube and colorimetric cup.
-
Independent operation It can save as many as
one hundred spectra, and can use PC to
process data via RS232 interface.
-
Multiple application software Four modules
dedicated for water quality measurement (CODCr,
Ammonia Nitrogen, Cyanide, and Chromium VI);
OEM Development of special software
according to customers’ requirements.
-
Complete accessories Configure various fiber-optics
accessories, and dedicated accessories for
water quality measurement.
Top of Page |
|
T90
AND T90+ DOUBLE BEAM UV VISIBLE SPECTROPHOTOMETER.

Specifications
|
1) Optical System: |
Double Beam |
|
- Wavelength range: |
190 nm – 900 nm |
|
- Variable Spectral bandwidth: |
0.1, 0.2, 0.5nm, 1.0nm, 2.0nm, and 5.0
nm. (Fixed 2nm Band pass on T90) |
|
- Stray Light: |
0.01%T |
|
- Wavelength accuracy: |
±0.3 nm (automatic correction) |
|
- Wavelength Reproducibility: |
0.1 nm |
|
2)
Photometric System: |
The double-beam ratio recording system. |
|
- Optical System: |
The monochromator of Czerny-Turner
configuration with high-resolution
diffraction holographic grating. |
|
- Photometric Method: |
Transmittance, absorbance, reflectance,
energy, concentration. |
|
- Photometric Range:
|
-4.0 ~ 4.0 Abs |
|
- Photometric Accuracy:
|
0.3%T 0.300%T |
|
- Photometric Reproducibility:
|
0.001Abs(0~0.5 Abs) 0.001Abs(0.5~1.0
Abs) 0.15%T (0~100%T), |
|
- Baseline flatness: |
±0.001Abs |
|
- Resolution: |
0.1nm |
|
- Baseline stability: |
0.0004Abs/h (@ 500nm, after preheating) |
|
- Absorbance Range: |
-9.999 to 9.999 ABS |
|
- Continuously variable spectral
bandiwth from: |
0.1, 0.2, 0.5, 1.0, 2.0 and 5.0 nm. |
|
-Scanning Speed:
|
1000 nm/min |
|
-Interface Card:
|
PC Compatible |
|
-Detector:
|
Hi sensivity R928 multiplier detector. |
|
-Photometric Display:
|
Unlimited |
|
-Photometric Noise:
|
<±0.0003 Abs (500nm, 0Abs, 2nm Bandwith) |
|
-Slew rate of wavelenght:
|
2400nm/min |
|
3)
DNA/RNA Measurement:
|
Available
in UV Win Software |
|
- Results Printout. |
Directly
form PC system. |
|
4)
Mainframe: |
Compact and standalone spectrophotometer
mainframe |
|
- Light Source: |
Socket Deuterium Lamp and Socket
Tungsten Halogen Lamp. |
|
- Sample Chamber: |
With accesories such as two-cell sample
holder and optional integrating sphere. |
|
- Size:
|
587mm. x 562mm. x 260mm. |
|
- Weight: |
34 Kg. |
Top of Page
|
|