T85 Spectrophotometer

The T85 is a Double Beam UV Visible Spectrophotometer with a wavelength range of 190 – 1100nm and a fixed Bandpass of 2nm (T85) OR a variable Bandpass of 0.5, 1.0, 2.0 and 5.0nm (T85+). The system is full controlled via an embedded touch screen PC pre-loaded with UVWin software.

Brochure Download

Brochure Download

UVWin Software (GLP)

Qualification Kit

Product Description

The NEW T85 Double Beam Spectrophotometer has  wavelength range of 190 – 1100nm with either a fixed 2nm bandpass (T85) or with a variable bandpass of o.5, 1.0, 2.0 and 5nm  (T85+). The instrument is supplied with an 8 cell motorized cell changer as standard. The T85 and T85+ are full controlled via an embedded touch screen Microsoft PC Tablet pre-loaded with UVWin 6 and with an Operating system of Windows 8 or 10.

  • T85 Double Beam Spectrophotometer With a wavelength range of 190-1100nm and either a fixed 2nm Bandpass (T85) or variable Bandpass 0.5 - 5nm T85+.
  • Touch Embedded PC fully Loaded with Windows 10 and UVWin 6.0 SoftwareYou can export data and store all results. The system has FOUR USB connectors for printers or interface to LIMS to Systems
  • Cell compartment for T85 for EIGHT 10 x 10mm Cells. Cell Changer is fully motorised. Large Cell compartment facilutates accesories such as Flow cells and Tablet Dissolution accessories.
  • Left Side view of T85
  • Right side view of T85
T85 Double Beam Spectrophotometer 1 Touch Embedded PC fully Loaded with Windows 10 and UVWin 6.0 Software2 Cell compartment for T85 for EIGHT 10 x 10mm Cells. 3 Left Side view of T854 Right side view of T855

Detailed Specification

Optical System Double Beam
Spectral Band width 2nm Fixed Bandpass (T85) and a variable bandpass of 0.5, 1.0, 2.0 and 5nm (T85+)
Scan Speed Selectable
Working Mode Embedded Touch Screen PC operating in Microsoft Windows 8(TM )
Software Support UV/Win Software v 6.0 (Full GLP version available on request)
Standard Functionality Photometric, Quantitative, Spectrum Scanning with 3D data representation and Kinetic measurements.
Wavelength Range 190 – 1100nm
Wavelength Accuracy ± 0.3nm (Automatic Wavelength Correction)
Wavelength Reproducibility 0.2nm
Stray Light ≤ 0.05% T (220nm Nal, 340nm NaNo2)
Photometric mode Transmission, Absorption and Energy
Photometric Range -0.3 – 3.0 Abs
Photometric Accuracy ± 0.002Abs (0-0.5A)

± 0.004Abs (0.5 -1.0A)

± 0.3%T (0-100%T)

Photometric Reproducibility 0.001Abs (0 – 0.5A)

0.002Abs (0.5 – 1.0A)

0.15%T (0 – 100%T)

Baseline Flatness ± 0.0015Abs (190 – 1100nm)
Baseline Stability 0.0008Abs/Hr (500nm, 0Abs, 2nm Spectral Bandwidth 2 hr warm up)
Photometric Noise ± 0.001Abs (500nm,0Abs, 2nm Spectral Bandwidth)
Power Supply Switchable 120 – 230vAC 50/60Hz

Product Enquiry