T60 Series |
T60NC |
T60-1651F |
5 cell holder (5-100mm) and 220V 50-60Hz
power supply |
Dual beam UV-Vis spectrophotometer |
 |
|
|
|
T60-1651E |
8 cell holder (10mm) and 220V 50-60Hz power
supply |
Wavelength Range: 190-1100nm, Spectral
bandwidth: 2nm |
|
|
|
|
T60-1652F |
5 cell holder (5-100mm) and 110V 50-60Hz
power supply |
Wavelength accuracy: ±1nm, Wavelength
repeatability: ≤0.2nm |
|
|
|
|
T60-1652E |
8 cell holder (10mm) and 110V 50-60Hz power
supply |
Photometric accuracy: ±0.3%T, Photometric
repeatability: ≤0.15%T |
|
|
|
|
|
|
Stray light: ≤0.05%T at 220nm(NaI) and at
340nm(NaNO2) |
|
|
|
T60 Aurora |
T60-1611F |
5 cell holder (5-100mm) and 220V 50-60Hz
power supply |
Dual beam Vis spectrophotometer |
|
|
|
|
T60-1611E |
8 cell holder (10mm) and 220V 50-60Hz power
supply |
Wavelength Range: 320-1100nm, Spectral
bandwidth: 2nm |
|
|
|
|
T60-1612F |
5 cell holder (5-100mm) and 110V 50-60Hz
power supply |
Wavelength accuracy: ±2nm, Wavelength
repeatability: ≤0.4nm |
|
| |
|
T60-1612E |
8 cell holder (10mm) and 110V 50-60Hz power
supply |
Photometric accuracy: ±0.3%T, Photometric
repeatability: ≤0.15%T |
|
|
|
|
|
|
Stray light: ≤0.1%T at 340nm(NaNO2) |
|
|
T70 Series |
T70 |
1820-2801-00 |
8 cell holder (10mm) and 110V or 220V
50-60Hz power supply |
Dual beam UV-Vis spectrophotometer |
 |
|
|
|
|
Dual beam, Spectral bandwidth: 2nm |
Wavelength Range: 190-1100nm, Spectral
bandwidth: 2nm |
|
|
|
|
|
|
Wavelength accuracy: ±0.5nm, Wavelength
repeatability: ≤0.2nm |
|
|
|
|
|
|
Photometric accuracy: ±0.3%T, Photometric
repeatability: ≤0.15%T |
|
|
|
|
|
|
|
|
|
|
T70+ |
1821-2801-00 |
8 cell holder (10mm) and 110V or 220V
50-60Hz power supply |
Dual beam UV-Vis spectrophotometer |
|
|
|
|
|
Dual beam, Spectral bandwidth: 5nm, 2nm,
1nm, 0.5nm |
Wavelength Range: 190-1100nm, Spectral
bandwidth: 5nm, 2nm, 1nm, 0.5nm |
|
|
|
|
|
|
Wavelength accuracy: ±0.5nm, Wavelength
repeatability: ≤0.2nm |
|
|
|
|
|
|
Photometric accuracy: ±0.3%T, Photometric
repeatability: ≤0.15%T |
|
|
|
|
|
|
|
|
|
T80 Series |
T80 |
1890-2801-00 |
8 cell holder (10mm) and 110V or 220V
50-60Hz power supply |
Double beam UV-Vis spectrophotometer |
 |
|
|
|
|
Double beam, Spectral bandwidth: 2nm |
Wavelength Range: 190-1100nm, Spectral
bandwidth: 2nm |
|
|
|
|
|
|
Wavelength accuracy: ±0.5nm, Wavelength
repeatability: ≤0.2nm |
|
|
|
|
|
|
Photometric accuracy: ±0.3%T, Photometric
repeatability: ≤0.15%T |
|
|
|
|
|
|
|
|
|
|
T80+ |
1891-2801-00 |
8 cell holder (10mm) and 110V or 220V
50-60Hz power supply |
Double beam UV-Vis spectrophotometer |
|
|
|
|
|
Double beam, Spectral bandwidth: 5nm, 2nm,
1nm, 0.5nm |
Wavelength Range: 190-1100nm, Spectral
bandwidth: 5nm, 2nm, 1nm, 0.5nm |
|
|
|
|
|
|
Wavelength accuracy: ±0.5nm, Wavelength
repeatability: ≤0.2nm |
|
|
|
|
|
|
Photometric accuracy: ±0.3%T, Photometric
repeatability: ≤0.15%T |
|
|
|
|
|
|
|
|
|
T90 Series |
T90+ |
0193-2801-00 |
Fixed cell holder (10mm) and 110V or 220V
50-60Hz power supply |
Double beam UV-Vis spectrophotometer |
 |
|
|
|
|
Double beam, Spectral bandwidth: 5nm, 2nm,
1nm, 0.5nm, 0.2nm, 0.1nm |
Wavelength Range: 190-900nm, Spectral
bandwidth: 5nm, 2nm, 1nm, 0.5nm, 0.2nm,
0.1nm |
|
|
|
|
|
|
Wavelength accuracy: ±0.3nm, Wavelength
repeatability: ≤0.15nm |
|
|
|
|
|
|
Photometric accuracy: ±0.3%T, Photometric
repeatability: ≤0.15%T |
|
|
|
|
|
|
Stray light: ≤0.02%T at 220nm(NaI) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
T100 series |
T100 |
T100 |
Portable spectrophotometer |
Single beam VIS spectrophotometer |
 |
|
|
|
|
|
Wavelength range: 380-800nm, Spectral
bandwidth: 4±1nm |
|
|
|
|
|
|
Wavelength accuracy: ±1nm, Wavelength
repeatability: ≤0.2nm |
|
|
|
|
|
|
Scanning speed: >4000nm/s |
|
|
|
|
|
|
|
|
|
|
T100+ |
T100+ |
Portable spectrophotometer |
Single beam VIS spectrophotometer |
|
|
|
|
|
|
Wavelength range: 200-800nm, Spectral
bandwidth: 4±1nm |
|
|
|
|
|
|
Wavelength accuracy: ±1nm, Wavelength
repeatability: ≤0.2nm |
|
|
|
|
|
|
Scanning speed: >4000nm/s |
|
|
|
|
|
|
|
|